Reimporting a skeletal mesh causes "use high precision tangent basis" & "use full precision UVs" to reset and no longer being applied to the mesh.
Reported and tested in version 4.25.3(CL 13942748). Issue not occurring in versions 4.24.3(CL 11590370) and 4.23.1(CL 9631420).
Result: Build settings for "use high precision tangent basis" & "use full precision UVs" reset to unchecked and are not applied to the mesh anymore.
Expected:Build settings for "use high precision tangent basis" & "use full precision UVs" stay checked and are still applied to the mesh.
i have this problem UE4CC-Windows-58DC12AF4B97F057BD108FBFF569B2E9_0000
I am not able to find world outliner how to enable it?
How can i modify the param name in EQS node
Delay nodes occasionally don't fire the "Completed" output in a nativized build
How to achieve HLSL Multiple Render Target in Material blueprints?
Undefined sysmbol: typeinfo for AActor when cross-compile linux dedicated server on windows
How to properly terminate the DoWork thread function in FAsyncTask?
There's no existing public thread on this issue, so head over to Questions & Answers just mention UE-99856 in the post.
0 |
Component | UE - Editor - Content Pipeline - Datasmith - Importer |
---|---|
Affects Versions | 4.25.3 |
Target Fix | 4.26 |
Created | Sep 17, 2020 |
---|---|
Resolved | Oct 14, 2020 |